DSO 1062S

750,00 

In stock

Hantek DSO 1062S (60 MHz) is a digital oscilloscope suitable for use in harsh industrial environments, but also for work in the field

Compare
SKU: HTH1062S Categories: , ,

Hantek DSO 1062S (60 MHz) Digital Handheld Oscilloscope

Impressive design, intuitive control and high-resistance finish make oscilloscopes in the 1000S series useful aiders not only in field work, but also in hard industrial conditions. All Hantek oscilloscopes offer a great price/performance ratio at the low-end segment of measuring technology and the DSO 1062S is no exception. The advantages of Hantek Handheld over its rival products are the more than five times larger sampling memory, very good interference resistance, more accurate mulitmeter offering a larger number of ranges, a higher quality color display with a longer diagonal 5.6“ (14.5 cm), intuitive control and a long lasting battery (6 hours for a single recharge).

DSO 1062S – main features:

      • Isolated Channels
    • Bandwidth: 60 MHz
  • Rise Time: 5.8ns
  • Sampling rate: 1 GS/s
  • Record Length: 1M
  • Measurement record storage (supports bitmap and CSV format)
  • USB Host: support removeable disk
  • Zoom function
  • Rise Time: 5.8ns
  • Sampling rate: 1 GS/s
  • Record Length: 1M
  • Measurement record storage (supports bitmap and CSV format)
  • USB Host: support removeable disk
  • Zoom function
    Multimeter function

  • 32 automatic measurements
  • Measuring cursors
  • Advanced trigger modes: Edge, Video, Pulse, Slope, Over time, Alternative
  • Screen storage
  • 5.6“ display with LED illumination; 640×480 point resolution
  • Dual-Window Design
  • LabVIEW support
  • Applications development support – Visual C, Visual Basic
  • Math functions including FFT
  • Quick offset calibration
  • LAN: Optional
  • Dimensions (mm): 240(L) x 165(W) x 50(H)

Multimeter parameters:

  • Number of digits: 6000
  • Measurement modes: U, I, R, f, diod test, continutity test
  • Max. input voltage – AC: 600 V DC: 800 V
  • Max. input current – AC: 10A DC: 10A
  • True-RMS multimeter
  • Input impedance: 10 M
  • Isolated input: up to 1000 V
  • Safety class: 1000 V CAT II and 600 V CAT III

Control Programme

The programme, which uses a pop-up menu, is user-friendly and easy to control. It is localized in English and includes a built-in help system. It features a whole range of standard functions frequently met with.

Linux support

  • Kernel version – Linux2.6.30.4
  • File system – Yaffs, Fat32
  • Drivers – Sound Driver, Buzzer Driver, FPGA Driver, SPI Driver, USB Host Driver, LCD Driver, USB Massstorage Gadget Driver
  • Applications – Busy Box 1.18.4, Mplayer, Watchdog, Gnupg1.4.11
  • U-boot – u-boot-1.1.6

The device will meet the needs of measuring technology professionals, but also those of technical secondary school and college students as a multifunction aid for study. Its low price and quality technical design offer a high use value.

Package contents:

    • This is a handheld digital storage oscilloscope, the Hantek DSO 1062S. It comes with two passive probes with 60 MHz bandwidth, a set of test probes for a multimeter, a 1.2-meter USB 2.0 connecting cable, a power adapter, and a high-quality nylon bag.

The oscilloscope has a sample rate range of 1 GS/s and uses (sin x)/x waveform interpolation. It has a maximum record length of 1 M samples per single channel or 512 K samples per dual channel (4 K, 16 K, 40 K optional). The time/div range is from 4 ns/div to 40 s/div, in a 2, 4, 8 sequence. The sample rate and delay time accuracy is ±50 ppm over any ≥1 ms time interval.

The delta time measurement accuracy (full bandwidth) is ±(1 sample interval + 100 ppm × reading + 0.6 ns) for single-shot normal mode and >16 averages is ±(1 sample interval + 100 ppm × reading + 0.4 ns). The position range for the DSO 1062B is from 4 ns/div to 8 ns/div, 20 ns/div to 80 μs/div, 200 μs/div to 40 s/div, and 2 ns/div to 10 ns/div.

The A/D converter has 8-bit resolution, and each channel is sampled simultaneously. The VOLTS range is from 2 mV/div to 5 V/div at the input BNC. The position range is from 2 mV/div to 200 mV/div, ±2 V for >200 mV/div to 5 V/div, and ±50 V. The analog bandwidth in normal and average modes at BNC or with a probe, DC coupled is 2 mV/div to 20 mV/div, ±400 mV, 50 mV/div to 200 mV/div, ±2 V, 500 mV/div to 2 V/div, ±40 V, and 5 V/div, ±50 V. The selectable analog bandwidth limit is typical at 20 MHz. The low-frequency response (-3dB) is ≤10 Hz at BNC. The rise time at BNC is typical, with less than 5.8 ns. The DC gain accuracy is ±3% for normal or average acquisition mode, 5 V/div to 10 mV/div, and ±4% for normal or average acquisition mode, 5 mV/div to 2 mV/div. The DC measurement accuracy, average acquisition mode, is ±(3% × reading + 0.1 div + 1 mV) when 10 mV/div or greater is selected for measurement type: Average of ≥16 waveforms with vertical position at zero.
Pulse Width Trigger ModeTrigger when < (Less than), > (Greater than), = (Equal), or ≠ (Not Equal); Positive pulse or Negative pulsePulse Width Trigger PointEqual: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level.
Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.
Less than: The trigger point is the trailing edge.
Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width.

Pulse Width Range Selectable from 20ns to 10s
Slope Trigger
Slope Trigger Mode Trigger when < (Less than), > (Greater than), = (Equal), or ≠ (Not Equal); Positive slope or Negative slope
Slope Trigger Point Equal: The oscilloscope triggers when the waveform slope is equal to the set slope.
Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope.
Less than: The oscilloscope triggers when the waveform slope is less than the set slope.
Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope.
Time Range Selectable from 20ns to 10s
Overtime Trigger The leading edge: Rising edge or Falling edge; Time Setting: 20-10s
Swap Trigger
CH1 Internal Trigger: Edge, Pulse Width, Video, Slope
CH2 Internal Trigger: Edge, Pulse Width, Video, Slope
Trigger Frequency Counter
Readout Resolution 6 digits
Accuracy (typical) ±30ppm (including all frequency reference errors and ±1 count errors)
Frequency Range AC coupled, from 4Hz minimum to rated bandwidth
Signal Source Pulse Width or Edge Trigger modes: all available trigger sources
The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed.
Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time.
Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity.
Video Trigger mode: The Frequency Counter does not work.

Acquisition

Acquisition Modes Normal, Peak Detect, and Average
Acquisition Rate, typical Up to 2000 waveforms per second per channel (Normal acquisition mode, no measurement)
Single Sequence Acquisition Mode Acquisition Stop Time
Normal, Peak Detect Upon single acquisition on all channels
simultaneously
Average After N acquisitions on all channels simultaneously, N can be set to 4, 8, 16, 32, 64 or 128

Inputs

Inputs
Input Coupling DC, AC or GND
Input Impedance, DC coupled 1MΩ±2% in parallel with 20pF±3pF
Probe Attenuation 1X, 10X
Supported Probe Attenuation Factors 1X, 10X, 100X, 1000X
Maximum Input Voltage Overvoltage Category Maximum Voltage
CAT I and CAT II 300VRMS (10×), Installation Category
CAT III 150VRMS (1×)
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.

Measurements

Cursors Voltage difference between cursors: △V
Time difference between cursors: △T
Reciprocal of △T in Hertz (1/ΔT)
Automatic Measurements Frequency, Period, Mean, Peak-to-peak, Cycle RMS, Minimum, Maximum, Rise Time, Fall Time, Positive Width, Negative Width

General Specifications

Display
Display Type 5.6 Inch width TFT Display
Display Resolution 480 (Vertical) X 640(Horizontal) pixels
Display Contrast Adjustable (16 gears) with the progress bar
Probe Compensator Output

Output Voltage, typical

About 5Vpp into ≥1MΩ load
Frequency, typical 1kHz
Power Supply
Switching Adatper AC Input:100-240VACRMS,0.6AMAX,50Hz-60Hz; DC Output:9V,2A
DC Input DC8.5-15V,2A
Power Consumption <30W
Environmental
Temperature Operating:32℉to122℉(0℃to50℃)
Nonoperating:-40℉to159.8℉(-40℃to +71℃)
Cooling Method Convection
Humidity +104℉or below (+40℃or below): ≤90% relative humidity
106℉to122℉(+41℃to50℃): ≤60% relative humidity
Altitude Operating and Nonoperating 3,000m(10,000 feet)
Random Vibration 0.31gRMS from 50Hz to 500Hz, 10 minutes on each axis
Nonoperating 2.46gRMS from 5Hz to 500Hz, 10 minutes on each axis
Mechanical Shock Operating 50g, 11ms, half sine
Mechanical
Size Length 245mm
Height 163mm
Depth 52mm
Weight

1.2 Kg

Meter Mode

Voltage,Current,Resistance,Capacitance,Diode & Continuity

Maximum Input Voltage

AC : 600V DC : 800V

Maximum Input Current

AC :10ADC :10A

Input Impedance

10MΩ

Meter Specification

Range Accuracy Resolution
DC Voltage 60.00mV(manual) ±1%±1digit 10uV
600.0mV 100uV
6.000V 1mV
60.00V 10mV
600.0V 100mV
800V 1V
AC Voltage 60.00mV(manual) ±1%±3digit 10uV
600.0mV(manual) 100uV
6.000V 1mV
60.00V 10mV
600.0V 100mV
DC Current 60.00mA ±1.5%±1digit 10uA
600.0mA ±1%±1digit 100uA
6.000A ±1.5%±3digit 1mA
10.00A 10mA
AC Current 60.00mA ±1.5%±3digit 10uA
600.0mA ±1%±1digit 100uA
6.000A ±1.5%±3digit 1mA
10.00A 10mA
Resistance 600.0 ±1%±1digit 0.1Ω
6.000K
60.00K 10Ω
600.0K 100Ω
6.000M 1KΩ
60.00M ±1.5%±3digit 10KΩ
Capacitance 40.00nF ±1%±1digit 10pF
400.0nF 100pF
4.000uF 1nF
40.00uF 10nF
400.0uF 100nF
Attention:The smallest capacitance value that can be measured is 5nF.
Diode 0V~2.0V
On-off Test

< 30Ω

Additional information

Weight 1 kg
Be the first to review “DSO 1062S”

Your email address will not be published. Required fields are marked *

Reviews

There are no reviews yet.

Main Menu