PASSIVE PROBE 200MHZ HANTEK PP-200

14,00 

92 skladem

Passive probe compatible with domestic and international digital and analog oscilloscopes in relevant frequency.

Compare
SKU: HT01114 Categories: ,

The hantek probe is a passive low-impedance attenuation probe.

The probe has been designed and calibrated for use on instuments having an input impedance of 1MΩ paralleled by 20pF.However, it may be recalibrated for use on instruments having an input capacitance of 15 ti 40pF.

The probe incorporates a two position (1X, 10X) slide switch in the compensating network and cable length of 1.2 meters.


Další informace

Hmotnost 1 kg
Model

Warranty

Parameters

<table style="width: 613px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="157" height="18">Item</td>
<td width="114">PP-80</td>
<td width="114">PP-90</td>
<td width="114">PP-150</td>
<td width="114">PP-200</td>
</tr>
<tr>
<td width="157" height="18">Attenuation</td>
<td colspan="4" width="456">x1  x10</td>
</tr>
<tr>
<td width="157" height="18">Input resistance</td>
<td colspan="4" width="456">1MΩ: <span>10MΩ</span></td>
</tr>
<tr>
<td width="157" height="38">Input capacitance</td>
<td colspan="2" width="228">x1: 85pF-115pF<br />x10:18.5pF-22.5pF</td>
<td colspan="2" width="228">x1: 85pF-115pF<br />x10: 18.5pF-22.5pF</td>
</tr>
<tr>
<td width="157" height="18">Compensation scope</td>
<td width="114">20pF-40pF</td>
<td width="114">15pF-40pF</td>
<td colspan="2" width="228">15pF-35pF</td>
</tr>
<tr>
<td width="157" height="32">System bandwidth</td>
<td width="114">x1:DC-4MHz;<br />x10: DC-60MHz</td>
<td width="114">x1:DC-6MHz;<br />x10: DC-80MHz</td>
<td width="114">x1: DC-5MHz<br />x10: DC-100MHz</td>
<td width="114">x1: DC-8MHz<br />x10: DC-200MHz</td>
</tr>
<tr>
<td width="157" height="36">Input voltage</td>
<td colspan="4" width="456">x1:<200V DC +Peak AC <br />x10: <600V DC +Peak AC</td>
</tr>
<tr>
<td width="157" height="18">weight</td>
<td colspan="4" width="456">55g</td>
</tr>
<tr>
<td width="157" height="18">Cable length</td>
<td colspan="4" width="456">120cm</td>
</tr>
<tr>
<td width="157" height="34">Temperature scope:</td>
<td colspan="4" width="456">Operation: -10<span>℃</span><span>–+50</span><span>℃<br /></span><span>Not Operation: -20</span><span>℃</span><span>–+75</span><span>℃</span></td>
</tr>
<tr>
<td width="157" height="19">Humidity</td>
<td colspan="4" width="456"><span>≤</span><span>85% (Relative humidity)</span></td>
</tr>
</tbody>
</table>

Be the first to review “PASSIVE PROBE 200MHZ HANTEK PP-200”

Vaše e-mailová adresa nebude zveřejněna. Vyžadované informace jsou označeny *

Reviews

There are no reviews yet.

PASSIVE PROBE 200MHZ HANTEK PP-200

14,00 

92 skladem

Passive probe compatible with domestic and international digital and analog oscilloscopes in relevant frequency.

Compare
SKU: HT01114 Categories: ,

The hantek probe is a passive low-impedance attenuation probe.

The probe has been designed and calibrated for use on instuments having an input impedance of 1MΩ paralleled by 20pF.However, it may be recalibrated for use on instruments having an input capacitance of 15 ti 40pF.

The probe incorporates a two position (1X, 10X) slide switch in the compensating network and cable length of 1.2 meters.


Další informace

Hmotnost 1 kg
Model

Warranty

Parameters

<table style="width: 613px;" border="0" cellspacing="0" cellpadding="0">
<tbody>
<tr>
<td width="157" height="18">Item</td>
<td width="114">PP-80</td>
<td width="114">PP-90</td>
<td width="114">PP-150</td>
<td width="114">PP-200</td>
</tr>
<tr>
<td width="157" height="18">Attenuation</td>
<td colspan="4" width="456">x1  x10</td>
</tr>
<tr>
<td width="157" height="18">Input resistance</td>
<td colspan="4" width="456">1MΩ: <span>10MΩ</span></td>
</tr>
<tr>
<td width="157" height="38">Input capacitance</td>
<td colspan="2" width="228">x1: 85pF-115pF<br />x10:18.5pF-22.5pF</td>
<td colspan="2" width="228">x1: 85pF-115pF<br />x10: 18.5pF-22.5pF</td>
</tr>
<tr>
<td width="157" height="18">Compensation scope</td>
<td width="114">20pF-40pF</td>
<td width="114">15pF-40pF</td>
<td colspan="2" width="228">15pF-35pF</td>
</tr>
<tr>
<td width="157" height="32">System bandwidth</td>
<td width="114">x1:DC-4MHz;<br />x10: DC-60MHz</td>
<td width="114">x1:DC-6MHz;<br />x10: DC-80MHz</td>
<td width="114">x1: DC-5MHz<br />x10: DC-100MHz</td>
<td width="114">x1: DC-8MHz<br />x10: DC-200MHz</td>
</tr>
<tr>
<td width="157" height="36">Input voltage</td>
<td colspan="4" width="456">x1:<200V DC +Peak AC <br />x10: <600V DC +Peak AC</td>
</tr>
<tr>
<td width="157" height="18">weight</td>
<td colspan="4" width="456">55g</td>
</tr>
<tr>
<td width="157" height="18">Cable length</td>
<td colspan="4" width="456">120cm</td>
</tr>
<tr>
<td width="157" height="34">Temperature scope:</td>
<td colspan="4" width="456">Operation: -10<span>℃</span><span>–+50</span><span>℃<br /></span><span>Not Operation: -20</span><span>℃</span><span>–+75</span><span>℃</span></td>
</tr>
<tr>
<td width="157" height="19">Humidity</td>
<td colspan="4" width="456"><span>≤</span><span>85% (Relative humidity)</span></td>
</tr>
</tbody>
</table>