| Model |
MSO5054FG |
MSO5054F |
| Acquisition |
| Sample Rate |
Real-Time Sample: 1GS/s |
| Acquisition Modes |
|
| Normal |
Normal data only |
| Peak Detect |
High-frequency and randon glith capture |
| Average |
Wavefom Average, selectable 4,8,16,32,64,128 |
| Inputs |
| Inputs Coupling |
AC, DC, GND |
| Inpits Impendance |
1MΩ±2% ‖20pF±3pF |
| Probe Attenuation |
1X, 10X |
| Supported Probe Attenuation Factor |
1X, 10X, 100X, 1000X |
| Maximum Input Voltage |
CAT I and CAT II: 300VRMS (10×), Installation Category; CAT III: 150VRMS (1×); Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above |
| Horizontal |
| Sample Rate Range |
1GS/s |
| Waveform Interpolation |
(sin x)/x |
| Record Length |
1M |
| SEC/DIV Range |
4ns/div to 40s/div, in a 2, 4, 8 sequence, |
Sample Rate and Delay Time Accuracy |
±50ppm(at over any ≥1ms time interval) |
| Position Range |
20ns/div to 80us/div; (-8div x s/div) to 40ms; 200us/div to 40s/div; (-8div x s/div) to 400s; |
Delta Time Measurement Accuracy (Full Bandwidth) |
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns); >16 averages:± (1 sample interval + 100ppm × reading + 0.4ns); Sample interval = s/div ÷ 200 |
| Vertical |
| Vertical Resolution |
8-bit resolution, all channel sampled simultaneously |
| Position Range |
2mV/div to 200mV/div, ±2V 200mV/div to 5V/div, ±50V |
| Bandwidth |
40MHz; |
| Rise Time at BNC( typical) |
8.8ns; |
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled |
2mV/div to 20mV/div, ±400mV 50mV/div to 200mV/div, ±2V 500mV/div to 2V/div, ±40V 5V/div, ±50V |
| Math |
+, -, *, /, FFT |
| FFT |
Windows: Hanning、Flatop、Rectamgular、Bartlett、Blackman; 1024 sample point |
| Bandwidth Limit |
20MHz |
| Low Frequency Response (-3db) |
≤10Hz at BNC |
| DC Gain Accuracy |
±3% for Normal or Average acquisition mode, 5V/div to 10mV/div; ±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div |
DC Measurement Accuracy, Average Acquisition Mode |
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for s |
Volts Measurement Repeatability, Average Acquisition Mode |
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions |
| Trigger System |
| Trigger Types |
Edge, Video, Pulse, Slope, Over time, Alternative |
| Trigger Source |
CH1, CH2, EXT, EXT/5, AC Line |
| Trigger Modes |
Auto, Normal, Single |
| Coupling Type |
DC, AC, Noise Reject, HF Reject, LF Reject |
Trigger Sensitivity (Edge Trigger Type) |
DC(CH1,CH2, CH3, CH4): 1div from DC to 10MHz;1.5div from 10MHz to Full; DC(EXT): 200mV from DC to Full; DC(EXT/5):1V from DC to Full; AC: Attenuates signals below 10Hz HF Reject: Attenuates signals above 80kHz; LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz |
| Trigger Level Range |
CH1, CH2, CH3, CH4: ±8 divisions from center of screen; EXT: ±1.2V; EXT/5:±6V |
| Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20ns |
CH1, CH2, CH3, CH4: 0.2div × volts/div within ±4 divisions from center of screen; EXT: ± (6% of setting + 40mV); EXT/5: ± (6% of setting + 200mV); |
| Set Level to 50%(typical) |
Operates with input signals ≥50Hz |
| Video Trigger |
|
| Video Trigger Type |
CH1, CH2, CH3, CH4: Peak-to-peak amplitude of 2 divisions; EXT: 400mV; EXT/5: 2V |
| Signal Formats and Field Rates, Video Trigger Type |
Supports NTSC, PAL and SECAM broadcast systems for any field or any line |
| Holdoff Range |
100ns ~ 10s |
| Pulse Width Trigger |
|
| Pulse Width Trigger Mode |
Trigger when (< , >, = , or ≠); Positive pulse or Negative pulse |
| Pulse Width Trigger Point |
Equal: The oscilloscope triggers when the trailing edge of the pulse crosses the trigger level. Not Equal: If the pulse is narrower than the specified width, the trigger point is the trailing edge. Otherwise, the oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width. Less than: The trigger point is the trailing edge. Greater than (also called overtime trigger): The oscilloscope triggers when a pulse continues longer than the time specified as the Pulse Width |
| Pulse Width Range |
20ns ~ 10s |
| Slope Trigger |
|
| Slope Trigger Mode |
Trigger when (< , > , = , or ≠ ); Positive slope or Negative slope |
| Slope Trigger Point |
Equal: The oscilloscope triggers when the waveform slope is equal to the set slope. Not Equal: The oscilloscope triggers when the waveform slope is not equal to the set slope. Less than: The oscilloscope triggers when the waveform slope is less than the set slope. Greater than: The oscilloscope triggers when the waveform slope is greater than the set slope. |
| Time Range |
20ns ~ 10s |
| Overtime Trigger |
|
| Over Time Mode |
Rising edge or Falling edge |
| Time Range |
20ns ~ 10s |
| Alternative Trigger |
|
| Trigger on CH1 |
Internal Trigger: Edge, Pulse Width, Video, Slope |
| Trigger on CH2 |
Internal Trigger: Edge, Pulse Width, Video, Slope |
| Trigger Frequency Counter |
|
| Readout Resolution |
6 digits |
| Accuracy (typical) |
±30ppm (including all frequency reference errors and ±1 count errors) |
| Frequency Range |
AC coupled, from 4Hz minimum to rated bandwidth |
| Signal Source |
Pulse Width or Edge Trigger modes: all available trigger sources The Frequency Counter measures trigger source at all times, including when the oscilloscope acquisition pauses due to changes in the run status, or acquisition of a single shot event has completed. Pulse Width Trigger mode: The oscilloscope counts pulses of significant magnitude inside the 1s measurement window that qualify as triggerable events, such as narrow pulses in a PWM pulse train if set to < mode and the width is set to a relatively small time. Edge Trigger mode: The oscilloscope counts all edges of sufficient magnitude and correct polarity. Video Trigger mode: The Frequency Counter does not work. |
| Measurement |
| Cursor Measurement |
Manual: Voltage difference between cursors: △V Time difference between cursors: △T Reciprocal of △T in Hertz (1/ΔT); Tracing: The valtage and time at a waveform point; |
| Auto Measuerment |
Frequency, Period, Mean, Pk-Pk, Cycli RMS, Minimum, Maximum, Rise time, Fall Time, +Pulse Width, -Pulse Width, Delay1-2Rise, Delay1-2Fall, +Duty, -Duty, Vbase, Vtop, Vmid, Vamp, Overshoot, Preshoot, Preiod Mean, Preiod RMS, FOVShoot, RPREShoot, BWIDTH, FRF |
| Display |
| Display Type |
7 inch 64K color TFT (diagonal liquid crystal) |
| Display Resolution |
800 horizontal by 480 vertical pixels |
| Display Contrast |
Adjustable (16 gears) with the progress bar |
| Logic Analyzer Specifications |
| Channels |
8 Channels |
| Max. Input Impendence |
200K(C=10p) |
| Input Voltage Range |
0V~3V |
| Logic Threshold Range |
0V~3V |
| Max. Sample Rate |
500MHz |
| Compatible Input |
TTL, CMOS, ECL |
| Sample Depth |
1M |
| Trigger |
|
| Edge Trigger |
D0-D7 select slope (rising or falling edge) |
| Pulse Width |
D0-D7 select pulse polarity (positive or negative pulse), trigger when (=, ≠, >, <), trigger pulse width |
| Code-type |
D0-D7 select code-type (H, L, X) |
| Duration |
D0-D7 select persist time and trigger when (data terminate, data start, and data delay) |
| Queue |
D0-D7 select specific data index (0-3) and code-type (H, L, X) |
| Repeat |
D0-D7 select code-type (H, L, X) and repeat times |
| Arb. Waveform Generator Specifications (MSO5054FG) |
| Wave frequency |
DC~25MHz |
| DAC clock |
2K~200MHz adjustable |
| Waveform Length |
4KSa |
| Vertical Resolution |
12 bit |
| Frequency stabilization |
<30ppm |
| Amplitude |
±3.5V Max. |
| Output impedance |
50 Ω |
| Output current |
50mA Ipeak=50mA |
| System Bandwidth |
25M |
| Wave distortion |
-50dBc(1KHz), -40dBc(10KHz) |
| Frequency area |
DC~50MHz |
| Input Amplitude |
400mVpp~18Vpp |
| Coupling |
DC |
| Frequency precision |
±Time Base Error ±1 Count |
| input impedance |
> 100KΩ |
| Pattern Generator |
12Bit |
| Probe Compensator Output |
| Output Voltage( typical) |
About 5Vpp into ≥1MΩ load |
| Frequency(typical) |
1kHz |
| General Features |
| Supply Voltage |
100-120VACRMS(±10%), 45Hz to 440Hz, CATⅡ 120-240VACRMS(±10%), 45Hz to 66Hz, CATⅡ |
| Power Consumption |
<30W |
| Fuse |
2A, T rating, 250V |
| Temperature |
Operating: 32℉ to 122℉ (0℃ to 50℃); Nonoperating: -40℉ to 159.8℉ (-40℃ to +71℃) |
| Cooling Method |
Convection |
| Humidity |
+104℉ or below (+40℃ or below): ≤90% relative humidity; 106℉ to 122℉ (+41℃ to 50℃): ≤60% relative humidity |
| Altitude |
Operating: Below 3,000m (10,000 feet); Nonoperaring: Below 15,000m(50,000 feet) |
| Size |
Length 385mm; Width 200mm; Height 245mm |
| Weight |
3.5KG(with Packing); 2.08KG(without Packing) |